- 18 -
3. Installation, Piping, and Wiring
■
Installation
z
Installation
Install the pump at a place where the ambient
temperature does not exceed 40ºC and the relative
humidity does not exceed 85%. (There should be no
dew condensation inside the control unit.) The place
should be convenient for future maintenance and
inspection. A sheltered location is recommended.
x
Place the pump as close to the suction tank as possible
so as to realize flooded suction piping (install the pump
at a lower level than the tank on the suction side).
c
Fix the pump firmly by means of m5 screws on a level
floor free from splashing liquid.
If the pump is inclined, the discharge may be decreased
or may even reach zero.
v
If the pump is used for a liquid that tends to generate air
bubbles (sodium hypochlorite, hydrazine solution, etc.),
make sure to install it in a cool, dark place away from
direct sunlight. When a tank, etc., is used, flooded
suction piping is required.
Discharge side
Suction side
Содержание EH-B10
Страница 16: ... 14 INSTALLATION 1 Before Use 15 2 Notes on Operation 15 3 Installation Piping and Wiring 18 ...
Страница 28: ... 26 PUMP OPERATION 1 Operation 27 2 Methodsn of Pump Operation 33 ...
Страница 61: ... 59 MEMO ...
Страница 62: ... 60 MEMO ...
Страница 63: ... 61 MEMO ...