z
Adjustment of stroke rate
The stroke rate is set by operating the control unit keys.
•
Adjust the stroke rate per minute of the plunger in the
range of 0 to 360 spm by the control unit.
x
Adjustment of stroke length
The stroke length is adjusted by changing the degree of
plunger return.
q
Turn the power on and adjust the discharge of the pump
by rotating the stroke length adjusting dial while the
pump is in operation.
w
The graph on the left shows the relation between
discharge and stroke length, which is shown in % of the
amount indicated on the nameplate as 100.
•
In practical use, set the stroke length in the range of 50
to 100%.
Do not rotate the stroke length adjusting dial when the
pump is out of operation.
- 31 -
Discharge
Adjusted stroke length
Fixed stroke rate
Discharge
Adjusted stroke length
Fixed stroke rate