EUROCARGO Euro 6
–
ELECTRONIC SUB-SYSTEMS
ELECTRONIC SUB-SYSTEMS
5.2
BODYBUILDER CONNECTORS
19
–
Printed 603.95.747
–
1st Ed. - Base 12/2013
open gateway). The Bodybuilder is responsible for initiating measures that make sure that the Safe State of its application is entered
autonomously.
When the application specifies that the Bodybuilder also requests a recovery strategy while the "Vehicle in full CAN option" output is
passive, contact IVECO if support is requested to complete the design specifications of this recovery strategy.
●
When in Customer Service a client specific programming have been required, then after each programming session the affected func-
tionality is to be checked and confirmed by the Bodybuilder.
●
The Bodybuilders have to ensure reliable design and wiring for all connections with the IVECO Bodybuilder interface.
Optional connector 72072B: 20 pin, black
A
B
190415
Figure 13
A.
500314809 Existing part on vehicle (male)
B.
500314816 Counterpart to be coupled (female)
Only available with OPT 0384 (EM-full) installed.
Basic functions of connector 72072B
Pin
Description
Wire
code
Max.
Load
Connected to
Remarks
1
Request gearbox in
neutral signal
0992
10 mA
(1)
EM X3-18
Only supported with OPT 6821 and AutoGbx.
Only if Bodybuilder Enable is also active (72072A/3).
Signal change needed, earliest 1 second after K15 ON.
Ground = active, low side switch
2
Bodybuilder Emergency
Signal
0993
10 mA
(1)
EM X3-19
Input to activate the Vehicle StoppedState values, only with Body-
builder Enable (72072A/pin 2) also activated
List of configurable signals
(2)
Ground = active, low side switch
3
External stop brake
request (EN1501)
0994
10 mA
(1)
EM X3-20
Only supported with opt 6821
(3)
Input to activate the Stopping brake (V<2km/h)
Ground = active, low side switch
4
Stop brake signal return
(EN1501)
0995
10 mA
EM X3-21
reserved for IVECO exclusively
Only supported with OPT 6821
Input to monitor the stop brake pressure
Ground = active, low side switch
5
Stepper swt req.
(EN1501)
0996
10 mA
(1)
EM X4-06
Only supported with opt 6821
(4)
Input to activate the Refuse stepper switch
Ground = active, low side switch
n.a. when ABS-HSA
(OPT 14861) installed
6
LMM (Light
Management Module)
Right direction light
6985
1.5 A
EM X1-03
Right turn signal light
0 V = not engaged
+24V = engaged
7
LMM (Light
Management Module)
Left direction light
6986
1.5 A
EM X1-08
Left turn signal light
0 V = not engaged
+24V = engaged
Содержание EUROCARGO
Страница 1: ...EUROCARGO EURO 6 M E D I U M R A N G E BODYBUILDERS INSTRUCTIONS ISSUE 2013 ...
Страница 4: ... Printed 603 95 747 Base 12 2013 ...
Страница 6: ... Printed 603 95 747 Base 12 2013 ...
Страница 8: ... Printed 603 95 747 Base 12 2013 ...
Страница 9: ... Printed 603 95 747 Base 12 2013 SECTION 1 GENERAL INFORMATION ...
Страница 10: ... Printed 603 95 747 Base 12 2013 ...
Страница 12: ...4 EUROCARGO Euro 6 GENERAL INFORMATION GENERAL INFORMATION Printed 603 95 747 1st Ed Base 12 2013 ...
Страница 28: ...20 EUROCARGO Euro 6 GENERAL INFORMATION GENERAL INFORMATION Printed 603 95 747 1st Ed Base 12 2013 ...
Страница 29: ... Printed 603 95 747 Base 12 2013 SECTION 2 CHASSIS INTERVENTIONS ...
Страница 30: ... Printed 603 95 747 Base 12 2013 ...
Страница 91: ... Printed 603 95 747 Base 12 2013 SECTION 3 APPLICATIONS OF SUPERSTRUCTURES ...
Страница 92: ... Printed 603 95 747 Base 12 2013 ...
Страница 135: ... Printed 603 95 747 Base 12 2013 SECTION 4 POWER TAKE OFFS ...
Страница 136: ... Printed 603 95 747 Base 12 2013 ...
Страница 138: ...4 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Страница 160: ...26 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Страница 161: ... Printed 603 95 747 Base 12 2013 SECTION 5 ELECTRONIC SUB SYSTEMS ...
Страница 162: ... Printed 603 95 747 Base 12 2013 ...
Страница 164: ...4 EUROCARGO Euro 6 ELECTRONIC SUB SYSTEMS ELECTRONIC SUB SYSTEMS Printed 603 95 747 1st Ed Base 12 2013 ...
Страница 215: ... Printed 603 95 747 Base 12 2013 SECTION 6 SPECIAL INSTRUCTIONS FOR SCR EXHAUST SYSTEM ...
Страница 216: ... Printed 603 95 747 Base 12 2013 ...
Страница 226: ... Printed 603 95 747 Base 12 2013 ...