6. MAINTENANCE
Cleaning the Static Bar
A clean brush with nylon bristles should be used to keep the ionization emitter points
of static bar clean. Periodic use of the brush will prevent deposits from accumulating
on the points. The emitter points must remain sharp for optimum operation.
NOTE
–Do not scrape points with any hard or sharp object that may
damage points.
A. Turn off power supply, or Control Station if used. Disconnect the blower from
line voltage.
B. Remove dirt particles deposited on static bar with a dry, stiff nylon bristle brush.
C. Blow off static bar with clean, dry compressed air.
D. Remove resistant coatings deposited on static bar by wiping with isopropyl
alcohol or mineral spirits applied to a clean cloth. Apply isopropyl alcohol or
mineral spirits to a stiff nylon bristle brush and thoroughly scrub the ionization
emitter channels of the bar.
E. Blow static bar dry with clean, dry compressed air and ensure the bar is
completely dry before re-applying power to bar.
NOTE
– Do not soak static bar or related components in alcohol or mineral
spirits. Do not use harsh solvents such as lacquer thinner, naphtha or
acetone.
CAUTION – Risk of Injury
Turn off the power supply and disconnect the blower from line voltage
before cleaning or removing the static bar. Use care handling the bar, sharp
pins present a puncture hazard.
Air Intake Filter
1. Filter cleaning or replacement frequency depends upon the cleanliness of the
operating environment. Inspect filters weekly, clean or replace as required.
2. Turn the blower and power supply OFF and remove air filter from intake.
3. The air filter is open cell polyurethane. It may be cleaned with mild soap and
water. Rinse thoroughly and allow to dry before reinstalling.
4. To install air filter, place over intake grille. Tuck edges of air filter into the three
filter clips.