IQ Power Fantom HL
5201305 Rev A
Bar Type
: A fixed description for the type of bar connected to the HL power supply
(speed).
Bar HV
: Allows turning internal HV power supplies on / off.
Ion Output
: Displays the ionization level, in percent, where Bar Calibration =
100% and the ionization level in terms of microamps for both positive and negative
ionization.
Balance
: A ratio of input power supplied to the high voltage power supplies that is
related to ion balance. In Fixed, Auto-Tune and CLFB modes this is a display only
and non-editable. The Balance may only be user adjusted in the Manual mode.
Operation Mode
: A user selectable operating mode for the static bar (Manual,
Fixed, Auto-Tune, CLFB).
•
Fixed
– 50/50 balance standard operation (default factory setting). Fixed
provides standard operation, with output voltage regulation.
•
Auto-Tune
– This mode is not recommended for use with the Fantom HL
blower.
•
CLFB (Closed-Loop Feedback)
– The best control of ion balance. The
IQ Power HL Sensor connected to an HL power supply will automatically
pair with that power supply for closed-loop control. The sensor must be
positioned to detect static at the target of neutralization in order for CLFB
to work. The sensor detects any charge imbalance at the target, or material
to be neutralized, then transmits this information to the static neutralizing
power supply. The power supply makes incremental changes to the balance
setting until target charges are minimized.
•
Manual
– Allows manual control of the ion balance. Manual mode includes
voltage regulation and current monitoring found in the standard mode, plus
manual control of the ion balance ratio. This mode of operation would only
be selected where the web, or material to be neutralized, exhibited extreme
and consistent charging of one polarity.
Mounting Distance
: A user entered value used only in the Auto-Tune mode. Not
recommended for use with the Fantom HL blower.
Web Speed
: A user entered value used only in the Auto-Tune mode. Not
recommended for use with the Fantom HL blower.
Device Address
: The Power Supply Number (address / device number) assigned to
the HL power supply. The address may be edited, but duplicate address numbers
are not permitted. The exception to this rule is static sensors. When a static Sensor
Interface is connected to an HL power supply (PS COMM 2) the Sensor Interface
will automatically be assigned the same address number as the HL power supply. On
the Control Station, the data from Sensors connected to that Sensor Interface will
appear as a tab under the HL power supply and the interface will automatically be
paired with that HL power supply for CLFB operation.