5. OPERATION
Apply AC power to the blower motor. Next, turn on the HL/HLC power supply
with the main power switch. If using a Control Station, turn on with the main
power switch located above the line cord. After the power supply goes through a
startup cycle, it will begin operating. The air outlet velocity may be adjusted with
the damper blades over the blower intake. Use the highest airspeed the application
allows. This insures quick discharge times and maximum coverage.
NOTE
– Before switching on power; ensure that units are properly
grounded and that static bars and sensors are properly installed.
HL Power Supply Indicators
Power
: Lights (green) to indicate power is on and the IQ Power HL Power Supply
is ready to operate.
Bar On
: Lights (green) to indicate when static neutralizing bar is active.
Fault
: Lights (red) to indicate faulty condition of static bar, power supply or high
voltage connections. Power will have to be turned off to clear the fault. When the
fault is cleared and power is restored, the fault light will be extinguished.
Clean Bar
: Lights (yellow) to indicate need to clean static bar. Clean Bar indicator
may light with low ion output (dirt build-up on ion emitters) or high output current
(conductive contamination on face of bar).
Output
: The (green) indicators are “Low”, “Medium” and “High” and light to
indicate the system relative ion output. The output will normally be in the high
and medium range. Low output generally indicates the need to clean the static bar.
Bar Type
: The (green) indicator next to “Speed” will illuminate when the bar is
connected.
Calibrate Locked
: The (green) indicator lights when the power supply is connected
to a Control Station and the Calibrate button on the HL power supply is locked out.
In this case, calibration must be performed through the Control Station.
HL Power Supply Operators
Calibrate
: Is a momentary push button switch located on the face label. Pressing
the face label firmly on “Calibrate” initiates calibration sequence and sets relative
nominal ion output for the system.