11
IQ Power Fantom HL
5201305 Rev A
Connect AC Adapter (AC adapter not required if power supply is connected to a
Control Station)
Make sure “POWER” switch on power supply is in “OFF” (0) position. Route low
voltage wire clear of moving machine parts and protect it from abrasion. Secure
using nylon wire ties (not supplied). Do not over tighten. Insert barrel connector
into “POWER IN” connector on power supply. Hand tighten barrel connector nut
to secure.
Connect line voltage to input side of AC adapter. The AC adapter is a universal
input type that accepts line voltage from 100 to 240 VAC 50/60 Hz. The AC
adapter line voltage connector accepts a line cord with an IEC 320 connector
(supplied). The line cord also provides electrical ground to the AC adapter. Check
electrical ground integrity in line voltage receptacle used for AC adapter. This
ground must not be defeated.
Figure 5. IQ Power Connections (Fantom HL to HL Power Supply)
Connect Power Supply Alarm Output (if used)
The IQ Power HL/HLC power supply “Alarm Output” is a standard DB25 pin
connector. A maximum distance of 3 meters [10 feet] or less is recommended. The
alarm output provides a variety of relay contact outputs that indicate the status of the
power supply. The relay contacts are rated for a maximum of 1A at 30 VDC. The
alarm output connector also provides a means of remote power in. (see Figure 6).