15
IQ Power Fantom HL
5201305 Rev A
Figure 9. IQ Power Crossover Modular Cable (black)
The IQ Power HL/HLC will report to the Control Station using the Power Supply
Number (address / device number). It will appear on the Control Station as a single
device. If an IQ Power HL Sensor Interface is paired with the HL/HLC, it will
appear as a tab on the device page.
If multiple IQ Power supplies are connected to the Control Station, each power
supply must have a unique Power Supply Number (address / device number). This
is necessary to enable reliable digital communication.
The Control Station can be used to automatically address the power supplies. The
default Power Supply Number for a new unit is “1”. Plug the first power supply into
the Control Station and turn Control Station on. Allow the Control Station to boot-
up and begin operation. Plug the second power supply into the Control Station.
The Control Station will re-address the second power supply to “2”. Plug the third
system into the Control Station. The Control Station will re-address the third power
supply to “3”. Repeat this process until all power supplies are installed. Each power
supply or device will be given a unique address (device number).
IQ Power HL/HLC power supplies may also be manually re-addressed through the
Control Station.
NOTE
–
DO NOT USE
standard Ethernet cables with IQ Power systems.
Avoid permanent equipment damage by using only Simco-Ion modular
cables. (Refer to Section 8, Parts and Accessories).