8
IQ Power Fantom HL
5201305 Rev A
Figure 3. HL/HLC Power Supply High Voltage Cable Termination
7. Place HV Connectors into HV plug bottom. The black plastic jacket should be
fully engaged in strain relief section of HV plug.
8. Install HV plug top onto bottom making sure plug comes together properly
with no binding or gapping. Hold together firmly.
9. Insert nylon screws through holes in plug bottom and tighten to secure plug
together (do not over tighten screws).
10. Plug in high voltage connector on static bar to HV1 or HV2 on power supply.
Secure high voltage connector with the (2) captive screws on the sides of
connector. Do not over-tighten.
NOTE
– Conduit seals must be properly installed to prevent the
propagation of vapors and flames through conduit runs (see Figure 2).
Outer (black) jacket of HV cables must be removed and (white) insulated
wires separated) before filling conduit seals with cement. Use care not to
nick or cut insulation on HV wires.
CAUTION – Electrical Shock Hazard
Do not connect static neutralizing bar with Power Supply energized.
Disconnect input power or switch power off before connecting static bar.
NOTE
– Failure to fully seat high voltage connectors into power supply
connectors may result in permanent damage to bar, cable or power supply.