![ITW Simco Ion IQ Power Fantom HL Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/itw/simco-ion-iq-power-fantom-hl/simco-ion-iq-power-fantom-hl_installation-and-operating-instructions-manual_2096662020.webp)
18
IQ Power Fantom HL
5201305 Rev A
Connect the HL Sensor Interface (if used)
An IQ Power HL Sensor may be integrated into the IQ Power system to provide
feedback on static eliminating performance and is used for the CLFB (Closed-
Loop Feedback) static eliminating mode. Cables for the Sensor Interface must be
IQ Power 8-conductor modular cables with RJ-45 connectors wired “crossover”
(reference color: black, Figure 9).
When using the IQ Power HL power supply, the modular cable plugs into one of the
connectors labeled “SI COMM 1” on the Sensor Interface and into the “PS COMM
2” connector on the HL power supply (see Figure 10). The second modular cable
plugs into one of the “PS COMM 1” connectors on the power supply and into one
of the connectors labeled “POWER & COMM” on the Control Station. The Sensor
Interface will now automatically pair with the IQ Power HL power supply.
When using the IQ Power HLC power supply, the modular cable plugs into one
of the connectors labeled “SI COMM 1” on the Sensor Interface and into the “PS
COMM 1” connector on the HLC power supply. (see Figure 11). The second
modular cable plugs into the other connector labeled “SI COMM 1” on Sensor
Interface and into one of the connectors labeled “POWER & COMM” on the
Control Station. The Sensor Interface must be manually addressed to the same
address of the HLC power supply in order to be paired.
Route modular cable clear of moving machine parts and protect it from abrasion.
Secure using nylon wire ties (not supplied). Do not over-tighten wire tie.
If there is an excess of modular cable, if possible, cut modular cable to length and
re-terminate using an RJ-45 connector installed with the same “polarization” as
connector removed (note rib / wire color code to modular connector).
See instructions included with IQ Power HL Sensor for sensor installation.
System Set-Up (without Control Station)
If the Fantom HL Blower is operating free standing (without connection to a
Control Station) set up is simply adjusting the air flow on target and adjusting the
blower output with the damper blades as necessary. Balance is factory calibrated.
System Set-Up (with Control Station)
A variety of information can be checked, and operating parameters set, for the IQ
Power HL/HLC power supply through the IQ Power Control Station via the device
page. Tap on device icon for the power supply and static bar to access these pages.
A summary tab will appear offering important information. Tabs for the neutralizer
and sensor (if installed) will also appear. Tapping on a neutralizer tab or sensor
tab opens a page where operating parameters may be edited or selected. Typical
parameters are listed below.
Device Name
: A user editable name to identify specific device (14 character).