5.14
Command Line Interface Management
Besides Web-based management, the iES6GF also supports Command Line Interface (CLI)
management. Use either the Console port or Telnet to manage the switch via the CLI. Details are
shown below.
CLI Management by RS-232 Serial Console (115200, 8, none, 1,
none)
Before configuring RS-232 serial console, connect the RS-232 port of the switch to your PC Com port
using a RJ45 to DB9-F cable.
Follow the steps below to access the console via RS-232 serial cable.
1)
Start
Tara Term
(or another terminal emulator) application.
2)
Under
Setup
select
Serial Port
.
Figure 142 - Tera Term VT interface
3)
Select the COM Port used by your PC to connect to the Console Port. Set the rest of the properties
to:
115200
for Baud rate,
8
for Data bits,
None
for Parity,
1
for Stop bits, and
none
for Flow control.
Then, click
OK
.