iES26GF
User’s
Manual
UM-iES26GF-1.2.3-EN.docx
Pages 8 of 169
Power Inputs
The iES26GF supports dual redundant, hot swappable power supplies, Power Supply 1 (PWR1)
and Power Supply 2 (PWR2). The connections for PWR1 and PWR2 are located on the terminal
block. To connect power, follow the steps below:
1)
Remove the cover designed for protection from the terminal block.
2)
Connect the ground from the first power source to GND1 terminal screw.
3)
Connect the Positive or Live from the first power source to the POWER 1 V+/L terminal
screw.
4)
Connect the Negative or Neutral from the first power source to the POWER 1 V-/N terminal
screw.
5)
If a redundant power supply is required repeat steps 2 to 4 connecting the wires from the
second power source to the POWER 2 terminal screws.
6)
To keep the wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-
clamp screws on the front of the terminal block connector.
7)
After wiring is completed, put the transparent cover back onto the terminal block
Figure 6 - Power Inputs