Commissioning
After the sensor is connected and installed, configure it via the display. The sensor is then ready for operation
and outputs the measuring value in mm to the screen. Optionally, the measuring field can be limited or the
switching output can be configured.
Connection
Installation
Application specific settings
(Optional settings)
Let's get started
Connection
Connect the sensor according to the connection
diagram. A shielded connection cable (8-pole M12)
must be used.
When everything is correctly connected, the sensor
starts up.
Legend function: 1 = n. c., 2 = L+, 3 = 4-20mA/0-10V, 4 = Push
Pull, 5 = Alarm Push Pull, 6 = n. c., 7 = L-, 8 = Hold
Legend colors: 1 = WH (white), 2 = BN (bronn), 3 = GN (green), 4
= YE (yellow), 5 = GY (gray), 6 = PK (pink), 7 = BU (blue), 8 = RD
(red)
Key functions
ESC
= Back
ESC 2 sec.
= Run mode
UP
= Up/increase value
DOWN
= Down/decrease value
SET
= OK
SET 2 sec.
= Save value
Slide over all 4 keys:
---->
= Enables the panel if locked
<----
= Jump to run mode
Setting the language
The language is selected and confirmed by pressing
SET for 2 seconds.
English
Deutsch
Italiano
Français
1
LANGUAGE
English
1
2
3
4