4
Installation
4.1 Mounting
The sensor has four mounting holes for flexible alignment and mounting. The use of 2 M4x35 screws is
recommended for mounting. The tightening torque is max. 1.2 Nm.
4.2 Sensor reference levels
To ensure easy alignment of the sensor during installation, the surfaces defined here are available:
The laser beam of the sensor runs parallel ( // ) to level R3 and is at a right angle to levels R1 and R2. Levels
R1, R2, and R3 serve as references for sensor alignment during installation. "Left" and "Right" designations
are also important.
Tightening torque
max. = 1.2 Nm
19 m
m
Level R3
Laser-
beam
Level R1
Level R2
13 mm
ATTENTION!
Connection, installation and commissioning may only be performed by qualified
personnel. Protect optical surfaces from moisture and dirt.
Left
Right