4.5 Mounting
The sensor can be installed at an inclination of up to ±30° to the reference surface. This is particularly useful
when space conditions do not allow any other installation option. See chapter FLEX MOUNT.
After activation of FLEX MOUNT, the sensor axis is no longer relevant. The measurement coordinate system
is now represented by the M and K axes. The height is now measured in M-direction.
4.5.1 Reference point with inclined installation
In the case of angled installation, the zero point (0 mm) of the K axis shifts out of the center of the measuring
field or the red visible laser line. Due to inclination of the sensor, the two measuring field sections, "measuring
field width left" and "measuring field width right", are no longer equal in size.
Reference point
K
M
Short
Long
NOTE
This fact is relevant where the position of the
reference point plays a role, e.g. with the FIELD OF
VIEW function. LIMIT LEFT and LIMIT RIGHT are
measured from this point.
0 … -30°
+30 … 0°
Reference surface