5.5.4 CORRECTION
The reference surface can be moved in height with CORRECTION after teaching. This is useful when using
an auxiliary plate, or if the reference surface has to be hidden.
Using an auxiliary plate
In this menu item, the reference surface is defined with due regard to the thickness of the auxiliary plate
(optional).
The surface taught in under TEACH REF is always the basis for this.
Example:
The display lights up red during TEACH REF because of unevenness in the reference surface. This reference
surface does not comply with one or more conditions.
A 10 mm thick auxiliary plate is therefore placed on the reference surface for the duration of the teach-in
process. Following activation of FLEX MOUNT and TEACH REF on this auxiliary plate, the auxiliary plate
must be specified with +10 mm in menu item CORRECTION. After completion of FLEX MOUNT, the reference
surface is now situated where the original (uneven) reference level was.
TEACH REF; taught-in surface
CORRECTION = thickness of the auxiliary plate
Auxiliary plate
Reference surface
This is the redefined reference surface, everything below it is suppressed