5.5 FLEX MOUNT (Function HEIGHT)
With FLEX¨MOUNT the reference surface will be teached-in. With respect of its inclination, the sensor is able
to calculate the height of objects correctly.
This function is recommended for the correct calculation of the height of objects with respect to the reference
surface.
With FLEX MOUNT the inclination angle and the distance from the reference surface are automatically
detected and saved in the sensor memory so the coordinate system can be rotated correctly. It is important
that the reached surface is even and covers as much of the entire measuring range of the sensor as possible.
FLEX MOUNT is used, if…
- a standard installation (right angle to the reference surface or the object) is not present
- the reference surface is closer to the sensor than the End of the measuring range Sde
- the reference surface is to be automatically taught in and/or shifted
- the background is to be suppressed
Effects
- The coordinate system is rotated
- The reference surface is teached-in; the original sensor reference point is no longer valid
- Objects below the reference surface are ignored
- The axes are no longer referred to as X and Z, but as M and K
- The angle symbol
appears on the left of the display when FLEX MOUNT is active
- SCALE OUT, DIGITAL OUT and FIELD OF VIEW are reset to factory settings
1
According to data sheet chapter 6.1
FLEX MOUNT angled
installation
Angle +30 … 0°
Reference surface
M K
Distance from the
reference surface
Distance from the
reference surface
NOTE
As soon as FLEX MOUNT is
activated, SCALE OUT, FIELD
OF VIEW and DIGITAL OUT
are reset to the standard
settings (SCALE OUT and
FIELD OF VIEW = maximum
measuring field, DIGITAL OUT
= End of measuring range