background image

User Guide for the

EVO96

DGP2-640

     DGP2-641BL / DGP2-641RB

  DGP2-648BL

Содержание Digiplex EVO DGP2-640

Страница 1: ...User Guide for the EVO96 DGP2 640 DGP2 641BL DGP2 641RB DGP2 648BL...

Страница 2: ......

Страница 3: ...s 12 User Options 14 Access Control User Options 15 Using Access Control 17 Entering Exiting 17 Arming and Disarming with Card 17 How Access Control Works 18 Trouble Display 19 Trouble Display 19 Even...

Страница 4: ...L RB keypad or the icons of the DGP2 640 and the DGP2 648BL LED display will let you assess the system status at a glance Your installer can even customize the messages for your home or business for t...

Страница 5: ...h detailed messages Use the arrow buttons to scroll through the current menu when the arrows appear in the LCD screen Action Buttons Each button s function is explained in the following sections of th...

Страница 6: ...efer to Stay Arming on page 6 Indicates the numerical values for the time sections zones options and codes Indicates which zones are in Chime Mode Refer to Programming Chime Zones on page 22 Indicates...

Страница 7: ...onfidential Mode Your installer can program keypads to not display the status of your system automatically by changing the keypad to Confidential Mode In Confidential Mode The zones status messages an...

Страница 8: ...xit In Area Status Display mode the following information will scroll on the LCD screen ready if all zones in the selected area are closed not ready if zones in the selected area are open Front Door O...

Страница 9: ...permit you to remain in your home or office by arming the outer zones perimeter of the protected area i e doors and windows To Stay arm 1 Enter your ACCESS CODE 2 Press the STAY button or the key 3 If...

Страница 10: ...ones cannot be bypassed 4 6 1 Bypass Recall Bypass Recall reinstates the zones that were bypassed the last time your system was armed To activate Bypass Recall 1 Enter your ACCESS CODE 2 Press the BYP...

Страница 11: ...the ACC button when the area you want to program appears on the screen 5 Enter the time you want the area to be armed according to the 24 hour clock i e 9 a m is 09 00 and 9 p m is 21 00 6 Press the...

Страница 12: ...m 1 Enter your ACCESS CODE 2 In the case of a false alarm call your monitoring station quickly to advise them of the false alarm In the case of a burglar alarm leave the premises and call the Police f...

Страница 13: ...using the DGP2 640 keypad The System Master Code has access to all Access Control doors and all Access Control features at all times Only the card s serial number and the choice of arming method can...

Страница 14: ...button on your DGP2 641BL RB keypad is assigned a set of letters To obtain the desired letter using the numeric buttons on your keypad press the button until the desired letter appears on the screen F...

Страница 15: ...r to Table 10 in Appendix 2 Russian Special Characters on page 28 If using a Greek keypad refer to Table 12 in Appendix 3 Greek Special Characters on page 29 Table 5 Special Characters Catalogue 6 5 D...

Страница 16: ...r Options refer to section 6 7 on page 14 8 Users are able to perform actions arming disarming etc only in the area s they are assigned To assign an area s to a user access code enter the number corre...

Страница 17: ...it a Half Beep when it switches to User Options Pre existing options will illuminate 6 Program the User Options by turning the options ON or OFF Once the options are programmed press the U key to reac...

Страница 18: ...the system A user that is not assigned to any partition but has the Access Control option Option 1 enabled can now gain access to an access control door by entering a code P I N and then pressing the...

Страница 19: ...Option 7 Code Follows Schedule When option 7 is ON users can use their access codes only during their scheduled hours assigned in step 8 in section 6 6 1 on page 13 When the option is OFF users can u...

Страница 20: ...2 Arming and Disarming with Card 7 2 1 Arming with Card presented to a door during its assigned Schedule refer to step 8 in section 6 6 1 on page 13 presented to a door within its assigned Access Lev...

Страница 21: ...r or the DGP2 641RB keypad on Door 02 on Tuesday August 3 at 3 00 p m she will gain access to the room Figure 4 Example B If Bonnie presents her card to the reader or the DGP2 641RB keypad on Door 02...

Страница 22: ...er s will illuminate 2 Press the NUMBER of the Trouble you wish to view We strongly suggest that if any troubles occur contact your installer immediately to have your system serviced 8 1 1 Group 1 Sys...

Страница 23: ...ctions that occurred in your system as well as any alarms or troubles i e Access Granted You will only be able to view the events that occurred in the area s assigned to your user access code Only ava...

Страница 24: ...3 Contrast refers to how dark or pale characters will appear on the screen Figure 6 Modifying LCD screen settings on the DGP2 641BL RB Figure 7 Modifying LCD screen settings on the DGP2 640 LCD ICON L...

Страница 25: ...our Chime zones to beep upon closure How do I program chime zones 1 Enter your ACCESS CODE 2 Press the 9 key 3 Press the 1 key to chime a zone Enter the number corresponding to the zone to be chimed o...

Страница 26: ...ture enabled will be able to access these functions To access the Quick Function Buttons 1 Enter your ACCESS CODE 2 Press the 0 button 3 Press the STAY or button to send a test report to the monitorin...

Страница 27: ...our system requires no maintenance other than regular testing We recommend that your installer change the battery every three years 10 4 System Test Speak to your installer before conducting a System...

Страница 28: ...moke detector 3 If the problem remains after 90 seconds the alarm will sound again Press CLEAR again 4 The system will delay reporting the alert for another 30 seconds If you are unable to cancel the...

Страница 29: ...g System Household fires are especially dangerous at night Fires produce smoke and deadly gases that can overcome occupants while they sleep To warn against fire install smoke detectors outside each s...

Страница 30: ...gramming the user labels of a Hebrew LCD keypad Instead of using Table 4 on page 11 and Table 5 on page 12 use Tables 9 and 10 below Refer to section 6 4 on page 11 for information on programming user...

Страница 31: ...ng the user labels of a Russian LCD keypad Instead of using Table 4 on page 11 and Table 5 on page 12 use Tables 11 and 12 below Refer to section 6 4 on page 11 for information on programming user lab...

Страница 32: ...c 115 s 131 147 163 179 195 211 227 e 243 y 020 036 052 4 068 D 084 T 100 d 116 t 132 148 164 180 196 212 G 228 z 244 w 021 037 053 5 069 E 085 U 101 e 117 u 133 149 165 181 197 213 229 h 245 q 022 03...

Страница 33: ...Tones Confirmation beep 2 in Opened or Closed Zones see Chime Zones Rejection beep 2 Bell Disconnected 19 Burglar Alarms 26 Buttons One Touch 7 Quick Function 23 Bypass Bypass Recall 7 Programming 7 C...

Страница 34: ...cial Characters 28 S Safety Tips Fire 25 Schedule Code Follows 16 Schedule Tolerance Window see Add Tolerance to User Schedule Schedules 13 Search Next Available Code 10 Siren Disconnected 19 Special...

Страница 35: ...e buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any ot...

Страница 36: ...2 0600 for French Monday to Friday from 8 00 a m to 8 00 p m EST For technical support outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 00 p m EST Please feel free...

Отзывы: