Sabre 1555 RFID and Bar Code Reader Service Manual
2-34
12. Place the upper case assembly onto the lower case.
Note: Be sure the flex cables are not pinched between the shells, and that the scan
window has been correctly located in the grooves on the front of the upper case
assembly.
13. Install six 4-40 x 0.75" Torx screws in the lower case to secure the shells together.
Torque the two screws closest to the scan window to 0.226 Nm (2.0 lb-in). Torque
the other four screws to .339 Nm (3.0 lb-in).
Torque to 0.226 Nm
(2.0 lb-in)
Torque to 0.339 Nm
(3.0 lb-in)
Torque to 0.339 Nm
(3.0 lb-in)
The reassembled 1555 is now ready for testing. For help, see the next chapter.