Replacing Parts in the 1555
2-9
2
9. Position the 1555 as shown. Hold the handle PCB in place with your thumb and
slide the handle base onto the PCB. Be sure the PCB is seated correctly in the
alignment grooves on one side of the handle.
Slide the handle PCB into
these alignment grooves
10. Install the handle assembly on the lower case using three 4-40 x 0.25" Torx screws.
Torque the screws to 0.791 Nm (7.0 lb-in).
11. For a standard 1555, reinstall the connecting cable on the bottom of the handle
assembly. For help, see the instructions that came with your connecting cable.
For a PDT 1555, install the extender wedge as described on page 2-4.
The 1555 for ready for testing. For help, see the next chapter.