Appendix A — Console Commands
EasyLAN Wireless User’s Manual
99
Parallel Port Console Commands
These commands let you configure and display Parallel Port parameters.
Parallel Port Console Commands
Command
Description
set port p1 ackh
status
Enables or disables Compatibility mode (ACKH,
1284 compatible) on the parallel port for older
printers. To use Compatibility mode, you must
disable ECP mode and Fast Strobe mode.
Where
status
is
en
for enabled or
dis
for disabled.
The default is enabled.
set port p1 bid
status
Enables or disables Bi-directional mode on the
parallel port. Where
status
is
en
for enabled or
dis
for disabled. The default is enabled.
set port p1 ecp
status
Enables or disables 1284 ECP mode on the parallel
port. If enabled, this mode takes priority over
Compatibility mode (ACKH) and Fast Strobe mode
(FSTB).
Where
status
is
en
for enabled or
dis
for disabled.
The default is enabled.
set port p1 fstb
status
Enables or disables Fast Strobe mode on the parallel
port. This mode handshake only with the busy line
from the printer. If enabled, this mode takes priority
over Compatibility mode (ACKH).
Where
status
is
en
for enabled or
dis
for disabled.
The default is disabled.
set port p1 inwt
status
Enables or disabled the Input Wait mode. If
enabled, this mode delays polling for input from the
printer at the end of a print job for one poll period.
Where
status
is
en
for enabled or
dis
for disabled.
The default is disabled.
set port p1 nbuf
status
Enables or disables no buffering on parallel port. If
this mode is enabled, data passes directly from the
network to the printer without buffering.
Depending on the network setup and application,
buffering may improve or reduce performance.
Where
status
is
en
for enabled or
dis
for disabled.
The default is enabled.
set port p1 noinbusy
status
Enables or disables the No Input While Busy mode.
If this mode is enabled, the printer is not polled for
data to send back to the host while reporting a busy
status on the interface.
Where
status
is
en
for enabled or
dis
for disabled.
The default is disabled.
set port p1 poll
nn
Amount of time (in ms) between input polls on the
parallel port. This value has an affect only when Bi-
directional mode is enabled. The default is 50 ms.
Содержание EasyLan AW02
Страница 1: ...EasyLAN Wireless User s Manual...
Страница 4: ...iv EasyLAN Wireless User s Manual...
Страница 8: ...Contents viii EasyLAN Wireless User s Manual...
Страница 96: ...Chapter 4 Troubleshooting EasyLAN Wireless 84 EasyLAN Wireless User s Manual...
Страница 117: ...EasyLAN Wireless User s Manual 105 Index I...
Страница 125: ......