Instance Configuration:
Object
Description
Level
See help on MEP create WEB.
Format
This is the configuration of the two possible Maintenance Association Identifier
formats.
ITU ICC
: This is defined by ITU. 'ICC' can be max. 6 char. 'MEG id' can be max. 7
char.
IEEE String
: This is defined by IEEE. 'Domain Name' can be max. 8 char. 'MEG
id' can be max. 8 char.
ICC/Domain Name
This is either ITU ICC (MEG ID value[1-6]) or IEEE Maintenance Domain Name -
depending on 'Format'. See 'Format'.
MEG Id
This is either ITU UMC (MEG ID value[7-13]) or IEEE Short MA Name -
depending on 'Format'. See 'Format'. In case of ITU ICC format this can be max.
7 char. If only 6 char. is entered the MEG ID value[13] will become NULL.
MEP Id
This value will become the transmitted two byte CCM MEP ID.
cLevel
Fault Cause indicating that a CCM is received with a lower level than the
configured for this MEP.
cMEG
Fault Cause indicating that a CCM is received with an MEG ID different from
configured for this MEP.
cMEP
Fault Cause indicating that a CCM is received with an MEP ID different from all
'Peer MEP ID' configured for this MEP.
cAIS
Fault Cause indicating that AIS PDU is received.
cLCK
Fault Cause indicating that LCK PDU is received.
cSSF
Fault Cause indicating that server layer is indicating Signal Fail.
aBLK
The consequent action of blocking service frames in this flow is active.
aTSF
The consequent action of indicating Trail Signal Fail to-wards protection is active.
Delete
This box is used to mark a Peer MEP for deletion in next Save operation.
Peer MEP ID
This value will become an expected MEP ID in a received CCM - see 'cMEP'.
Unicast Peer MAC
This MAC will be used when unicast is selected with this peer MEP. Also this
MAC is used to create HW checking of receiving CCM PDU (LOC detection) from
this MEP.
Содержание NS4702-24P-4S-4X
Страница 1: ...NS4702 24P 4S 4X User Manual P N 1072829 REV 00 01 ISS 14JUL14 ...
Страница 23: ...23 Storage Temperature 10 70 degrees C Relative Humidity 5 95 non condensing ...
Страница 164: ...164 Figure 4 8 2 Multicast Flooding ...
Страница 183: ...183 Figure 4 8 14 IGMP Snooping VLAN Configuration Page Screenshot ...
Страница 189: ...189 Figure 4 8 17 MLD Snooping Groups Information Page Screenshot ...
Страница 203: ...203 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 208: ...208 Figure 4 9 6 QoS Egress Port Tag Remarking Page Screenshot ...
Страница 218: ...218 Deletes the QCE The lowest plus sign adds a new entry at the bottom of the list of QCL ...
Страница 229: ...229 Figure 4 9 18 Voice VLAN Configuration Page Screenshot ...
Страница 252: ...252 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 291: ...291 measurement is 100 ms A value of 0 ms indicates that there hasn t been round trip communication with the server yet ...
Страница 299: ...299 Figure 4 11 17 Add User Properties Screen Figure 4 11 18 Add User Properties Screen ...
Страница 336: ...336 Figure 4 14 2 LLDPMED Configuration Page Screenshot ...
Страница 357: ...357 Figure 4 15 4 VeriPHY Cable Diagnostics Page Screenshot ...
Страница 367: ...367 ...
Страница 375: ...375 Figure 4 16 10 Port Power Consumption Screenshot Buttons Click to refresh the page immediately ...
Страница 391: ...391 ...