239
The allowed range is
0x0
to
0xff
.
Frame Type
Select the frame type for this ACE. These frame types are mutually exclusive.
■
Any
: Any frame can match this ACE.
■
Ethernet Type
: Only Ethernet Type frames can match this ACE. The IEEE
802.3 describes the value of Length/Type Field specifications to be greater
than or equal to 1536 decimal (equal to 0600 hexadecimal).
■
ARP
: Only ARP frames can match this ACE. Notice the ARP frames won't
match the ACE with ethernet type.
■
IPv4
: Only IPv4 frames can match this ACE. Notice the IPv4 frames won't
match the ACE with ethernet type.
■
IPv6
: Only IPv6 frames can match this ACE. Notice the IPv6 frames won't
match the ACE with ehternet type.
Action
Specify the action to take with a frame that hits this ACE.
■
Permit
: The frame that hits this ACE is granted permission for the ACE
operation.
■
Deny
: The frame that hits this ACE is dropped.
Rate Limiter
Specify the rate limiter in number of base units.
The allowed range is 1 to 16.
Disabled indicates that the rate limiter operation is disabled.
Port Redirect
Frames that hit the ACE are redirected to the port number specified here.
The allowed range is the same as the switch port number range.
Disabled indicates that the port redirect operation is disabled.
Logging
Specify the logging operation of the ACE. The allowed values are:
■
Enabled
: Frames matching the ACE are stored in the System Log.
■
Disabled
: Frames matching the ACE are not logged.
Note
: The logging feature only works when the packet length is less than 1518(without
VLAN tags) and the System Log memory size and logging rate is limited.
Shutdown
Specify the port shut down operation of the ACE. The allowed values are:
■
Enabled
: If a frame matches the ACE, the ingress port will be disabled.
■
Disabled
: Port shut down is disabled for the ACE.
Note
: The shutdown feature only works when the packet length is less than
1518(without VLAN tags).
Counter
The counter indicates the number of times the ACE was hit by a frame.
Содержание NS4702-24P-4S-4X
Страница 1: ...NS4702 24P 4S 4X User Manual P N 1072829 REV 00 01 ISS 14JUL14 ...
Страница 23: ...23 Storage Temperature 10 70 degrees C Relative Humidity 5 95 non condensing ...
Страница 164: ...164 Figure 4 8 2 Multicast Flooding ...
Страница 183: ...183 Figure 4 8 14 IGMP Snooping VLAN Configuration Page Screenshot ...
Страница 189: ...189 Figure 4 8 17 MLD Snooping Groups Information Page Screenshot ...
Страница 203: ...203 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 208: ...208 Figure 4 9 6 QoS Egress Port Tag Remarking Page Screenshot ...
Страница 218: ...218 Deletes the QCE The lowest plus sign adds a new entry at the bottom of the list of QCL ...
Страница 229: ...229 Figure 4 9 18 Voice VLAN Configuration Page Screenshot ...
Страница 252: ...252 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 291: ...291 measurement is 100 ms A value of 0 ms indicates that there hasn t been round trip communication with the server yet ...
Страница 299: ...299 Figure 4 11 17 Add User Properties Screen Figure 4 11 18 Add User Properties Screen ...
Страница 336: ...336 Figure 4 14 2 LLDPMED Configuration Page Screenshot ...
Страница 357: ...357 Figure 4 15 4 VeriPHY Cable Diagnostics Page Screenshot ...
Страница 367: ...367 ...
Страница 375: ...375 Figure 4 16 10 Port Power Consumption Screenshot Buttons Click to refresh the page immediately ...
Страница 391: ...391 ...