![Interlogix NS4702-24P-4S-4X Скачать руководство пользователя страница 217](http://html.mh-extra.com/html/interlogix/ns4702-24p-4s-4x/ns4702-24p-4s-4x_user-manual_2077364217.webp)
217
■
Unicast
: Only Unicast MAC addresses are allowed.
■
Multicast
: Only Multicast MAC addresses are allowed.
■
Broadcast
: Only Broadcast MAC addresses are allowedd.
The default value is 'Any'.
SMAC
Displays the OUI field of Source MAC address, i.e. first three octet (byte) of MAC
address.
Tag Type
Indicates tag type. Possible values are:
■
Any
: Match tagged and untagged frames.
■
Untagged
: Match untagged frames.
■
Tagged
: Match tagged frames.
The default value is 'Any'
VID
Indicates (VLAN ID), either a specific VID or range of VIDs. VID can be in the
range 1-4095 or 'Any'
PCP
Priority Code Point: Valid value PCP are specific(0, 1, 2, 3, 4, 5, 6, 7) or
range(0-1, 2-3, 4-5, 6-7, 0-3, 4-7) or 'Any'.
DEI
Drop Eligible Indicator: Valid value of DEI can be any of values between 0, 1 or
'Any'.
Frame Type
Indicates the type of frame to look for incomming frames. Possible frame types
are:
■
Any
: The QCE will match all frame type.
■
Ethernet
: Only Ethernet frames (with Ether Type 0x600-0xFFFF) are
allowed.
■
LLC
: Only (LLC) frames are allowed.
■
SNAP
: Only (SNAP) frames are allowed.
■
IPv4
: The QCE will match only IPV4 frames.
■
IPv6
: The QCE will match only IPV6 frames.
Action
Indicates the classification action taken on ingress frame if parameters
configured are matched with the frame's content.
There are three action fields: Class, DPL and DSCP.
■
Class
: Classified QoS class.
■
DPL
: Classified Drop Precedence Level.
■
DSCP
: Classified DSCP value.
Modification Buttons
You can modify each QCE in the table using the following buttons:
: Inserts a new QCE before the current row.
: Edits the QCE.
: Moves the QCE up the list.
: Moves the QCE down the list.
Содержание NS4702-24P-4S-4X
Страница 1: ...NS4702 24P 4S 4X User Manual P N 1072829 REV 00 01 ISS 14JUL14 ...
Страница 23: ...23 Storage Temperature 10 70 degrees C Relative Humidity 5 95 non condensing ...
Страница 164: ...164 Figure 4 8 2 Multicast Flooding ...
Страница 183: ...183 Figure 4 8 14 IGMP Snooping VLAN Configuration Page Screenshot ...
Страница 189: ...189 Figure 4 8 17 MLD Snooping Groups Information Page Screenshot ...
Страница 203: ...203 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 208: ...208 Figure 4 9 6 QoS Egress Port Tag Remarking Page Screenshot ...
Страница 218: ...218 Deletes the QCE The lowest plus sign adds a new entry at the bottom of the list of QCL ...
Страница 229: ...229 Figure 4 9 18 Voice VLAN Configuration Page Screenshot ...
Страница 252: ...252 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 291: ...291 measurement is 100 ms A value of 0 ms indicates that there hasn t been round trip communication with the server yet ...
Страница 299: ...299 Figure 4 11 17 Add User Properties Screen Figure 4 11 18 Add User Properties Screen ...
Страница 336: ...336 Figure 4 14 2 LLDPMED Configuration Page Screenshot ...
Страница 357: ...357 Figure 4 15 4 VeriPHY Cable Diagnostics Page Screenshot ...
Страница 367: ...367 ...
Страница 375: ...375 Figure 4 16 10 Port Power Consumption Screenshot Buttons Click to refresh the page immediately ...
Страница 391: ...391 ...