29
System wiring diagram
[Note] Please refer to “3. Product wiring diagram”for detailed wiring diagram.
26
Step 3. Basic function tests
1. Perimeter gate station call guard unit
Press # on perimeter gate station to call guard unit and guard unit answers.
Malfunction 1
, perimeter gate station shows: Fail-2.
● Check the wiring between perimeter gate station and switch.
Malfunction 2
. Perimeter gate station shows: Fail-11.
● Check wiring between guard unit and switch.
Malfunction 3
. Guard unit ringing, but no image, perimeter gate station no ringing.
● Check wh
ether the indicator light on switch for guard unit and perimeter gate station port is on or off. If the indicator light is on,
but it is not the same as the wiring port, check the setup form of perimeter gate station and guard unit, check whether they are
in accordance with the actual wiring.
2. Door station
(
LCD
)
calling guard unit
Press # key on door station to call guard unit, and guard unit answers.
Malfunction 1
. Door station shows: Fail-2
● Check wiring between door station and gate
-way.
Malfunction 2
. Door station shows : Fail-9.
● Check wiring between s
witch and gate-way
Malfunction 3
. Door station shows: Fail-11.
● Check wiring between guard unit and switch
Malfunction 4
. Guard unit ringing, but no image, door station no ringing
● Check whether the indicator light on switch for guard unit and gate
-way port is on or off. If the indicator light is on, but it is not the
same as the real wiring port, check the setup form of door station and guard unit, check whether they are in accordance with the
actual wiring or not.
Malfunction 5
. The door station no. shows on the guard unit is not the same with reality.
● Check whether the door station setup form is in accordance with the actual wiring
or not.
2-2.
Door station
(
LED
)
calling guard unit
Press # key on door station to call guard unit, and guard unit answers.
Malfunction 1
. Door station shows: Err2
● Check wi
ring between door station and gate-way.
Malfunction 2
. Door station shows: Err9
● Check wiring between switch and gate
-way
Malfunction 3
. Door station shows: Err11
● Check wiring between guard unit and switch
Malfunction 4
. Guard unit ringing, but no image, door station no ringing
● Check whether the indicator light on switch for guard unit and gate
-way port is on or off. If the indicator light is on, but it is not the
same as the real wiring port, check the setup form of door station and guard unit, check whether they are in accordance with the
actual wiring or not.
Malfunction 5
. The door station no. shows on the guard unit is not the same as reality.
● Check whether the door station setup form is in accordance with the actual wiring
or not.
2-3.
Direct-call door station calling guard unit
Press # key on door station to call guard unit, and guard unit answers.
Malfunction 1
. Door station sounds short “di” “di” “di”.
● Check wiring between door station and gate
-way.