11
Door station lock diagram
System provides two ways of electric lock connection for user to choose: Power unlock and signal unlock. (Note: For oversea market,
always use the signal unlock).
1. Power unlock
2. Signal unlock
Normal open type lock wiring
Normal closed type lock wiring
[Note] This way of unlocking needs DC12V separate power supply.
3. Exit button unlocking
4. Door alarm diagram
Connect the door station [GS] terminal to the door alert sensor as follows show, the door station will send alarm message to managing
center if the door is opened for more than 120s.
[Note] There are two methods to switch this function OFF.
1. Connect the [GS] terminal to earth.
2. Refer to the “Appendix 1~2. door station operation explanation”
→ “Alarm Setting” to set it OFF.
Short circuit
Power supply
Power supply
Door station terminal
Door station terminal
Door station terminal
Electric lock
Electric lock
Magnetic lock
44
Press [F1] button, enter the menu
The LCD displays as P2. Input the system password.
[Note] The system original password is 2003. Please refer to
“System PW”to change it.
System Setting
If the password is correct, it will enter P3 automatically, here can
proceed system functions setting.
[ # ]
:
Confirm
[ * ]
:
Quit
Restore Default Password
Hold [*] button on the door station, then connect the power, the
default password will be restored. And the LCD will show the
version number of software.
[Note] The P1 is for example.
This door station has series of functions, and each function has
its own function form.
(1)
(2)
(3)
(7)
(4)
(5)
(6)
■
Door station setting
In the menu of P3
, input
0
#
, enter the door station number
setting, it will show as P7 for the first time setting.
Input door station number, e.g.:0101
Input the gate-way port which connect to the door station, e.g.: 1
Press [#] button to confirm, it will automatically return to P2.
[Note] Door station’
s No. is from 0001, Port No. of gate-way please
refer to the port of gate-way connected to door station.
2. Cancel gate-way data
1. Cancel all indoor phone No.
In P3, input [1]+[#] , then input [2]+[#] to clean all the indoor
phone information. The LCD will shows as P4 during process.
If clearance successful, a long sound of “di” can be heard and
LCD shows as P5, press [*] button to back to menu of P3.
[
] This function is used in the first time setting only.
Data clearance
For first time setting, system data clearance is needed
In the menu of P3, input [6]+[#] to clear the information in the
gate-way. After clearance, a long sound of “di” can be heard and
the LCD shows as P6, press [*] button to back to menu of P3.