43
Appendix 2. LED door station operation explanation
Enter System
[
F1]
Door station [0+#]
Indoor phone [1+#]
Single Input
[0+#]
Matrix Input
[1+#]
Clear Data
[2+#]
Bit
[3+#]
Alarm Setting [2+#]
Card
[3+#]
Register Single [0+#]
Register Patrol [2+#]
Delete Single
[3+#]
Delete All
[5+#]
PW unlock
[4+#]
Unlock Time
[5+#]
System PW
[6+#]
Public PW
[7+#]
Menu
Upload
[4+#]
Download
[5+#]
Clear Gate-way [6+#]
Restore Default Password [
*]
Private PW [F2]
Lift Setting
[8+#]
Lift
[0+#]
Floor Setting
[1+#]
12
4. System programming
According to product wiring diagram, connect all the parts and then start system programming. Programming should follow the
sequence from a building to network system. Programming products in a building first, then program system products in network.
Building programming
First step: Hardware setting
This step is to set address for gate-way and distributor.
[Note] 1. All the gate-way number which connect to the same port of switch should not be repeat.
2. All the distributor number which connect to the same gate-way should not be repeat.
3. Please take record of the gate-way number and distributor number, these information may be used in the coming setting.
■
Address gate-way (Set gate-way number)
1. DIP switch (it is in the cover plate on the left side of gate-way), show as below:
2. Address range :001~063
3. Address calculating: According to the form below, plus all the number that is on the [ON] position, and you will get the address
number.
DIP
1
2
3
4
5
6
7
8
Digits
1
2
4
8
16
32
none none
[Note] When setting address, please according to sequence of unit order to set numbers/digits(DIP 7-8 is invalid, and can not be set on
[ON] position to the DIP7 and DIP8.)
e.g.:
From the above picture, the digit is =2+4+8=14, so the gate-way’s address/number is 014.
■
Address distributor (Set distributor number)
1. DIP switch (it is in the cover plate on the left side of distributor), show as below pictures
2. Address range :001~254
3. Address calculating: According to below form, add all digits on [ON] position to get the address number.
DIP
1
2
3
4
5
6
7
8
Digit
1
2
4
8
16
32
64
128