79
OPERATION INSTRUCTION
Search 3 range
Search 1 range
Search Parameters
Setup mode
Manual search MODE
Antenna MODE
Search param
S E T U P M O D E ?
4
Y E S N O
1. Press the LEFT arrow key to move the cursor to YES and press the OK key to enter
SETUP mode.
4
+ A N T E N N A + S A T E L L I T E
+ S Y S T E M + I N S T A L L A T I O N
2. Press the OK key to enter the ANTENNA menu.
+ M A N U A L S E A R C H + S E T P O L A N G L E
4
+ S E A R C H P A R A M + S E T P A R A M E T E R S
3. Press the DOWN arrow keys to move the cursor to SEARH PARAM and press the OK key
to select it.
S E A R C H W A I T T I M E I N C R E M E N T S T E P
0 3 0
0 . 5 0
4. Set the SEARCH WAIT TIME and INCREMENT STEP
Set the time-out for automatic initiation of a search after the signal level drops below the
predefined threshold value (Range : 1 - 120 sec)and set the increment step size (Range :
0.01 – 5.00 sec).
S E A R C H 1 A Z S E A R C H 1 E L
4 0 0
0 6
S E A R C H 3 A Z S E A R C H 3 E L
0 0 3
0 4
5. Set the SEARCH 1 and 3 AZ (Azimuth) range and EL (Elevation) range.
SEARCH 2 is reserved for future use.
Содержание v240M
Страница 2: ......
Страница 4: ...INDEX...
Страница 7: ...7 Intellian v240M Introduction Intellian v240M Features System Configuration INTRODUCTION...
Страница 12: ...v240M Marine Satellite Communication System 12...
Страница 52: ...v240M Marine Satellite Communication System 52...
Страница 66: ...v240M Marine Satellite Communication System 66...
Страница 124: ...v240M Marine Satellite Communication System 124 Figure 106 Satellite View Tab for s80HD and t240CK...