2 Safety information copper tests
ARGUS Copper Test Manual
7
Longitudinal conversion loss (LCL)/NEXT
Before measuring, make sure that the voltage thresholds given in the table below are not
exceeded during the measurement. When measuring LCL or NEXT using the ARGUS,
any type of additional measurement lead can falsify the measurement. Both the length
and the position of the measurement leads with respect to each other can influence the
measurement result significantly.
Signature detection/fast cable check/remote kit control
Before measuring, make sure that the voltage thresholds given in the table below are not
exceeded during the measurement.
Voltage thresholds
Measurement
UDC (V) to
UAC (Veff) to
R*
3,5
30
R-Sym*
30
30
ISO-R*
5
30
C*
17
17
C-Sym*
17
17
LCL
10
7
NEXT
10
7
Signature
3
3
Fast cable check**
5
30
Remote Box
3
3
* Measured on 200 kΩ load
** Loop limit value 10 kΩ