![Intec ARGUS 260 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/intec/argus-260/argus-260_manual_2070524056.webp)
3 Copper tests
56
ARGUS Copper Test Manual
3.3.2 Examples
The following signal forms can help you in interpreting the reflection responses that
ARGUS displays.
Open cable
The reflected pulse is positive. No proxi-
mate interference sources or the far end of
the line can be seen.
Short-circuit
The reflected pulse is negative. No proxi-
mate interference sources or the far end of
the line can be seen.
Mismatch
Different line cross-sections were used.
The greater the mismatch, the greater the
amplitude of the reflection.
Poor contact point
A poor contact between two lines distorts
the reflection into an S-shape. The worse
the contact, the greater the reflection.