3 Copper tests
16
ARGUS Copper Test Manual
See the chapter Technical data page 8 for information on measuring ranges, resolutions
and accuracies of voltage measurement.
Capacitive symmetry measurement settings
Selection of the capacitive symmetry measurement
After activating the capacitive symmetry measurement, the following is measured:
- Cm (operating (mutual) capacitance) (in nF)
- Cab (capacitance between Tip and Ring) (in nF)
- CaE (capacitance between Tip and Ground) (in nF)
- CbE (capacitance between Ring and Ground) (in nF)
- ΔC (absolute deviation between CaE and CbE) (in nF)
- Relative deviation (in %)
After selecting the "Menu" softkey, the following settings can be made:
- Wire Types
- Susceptibility
- Remote Kit Command
- Remote Kit
You can obtain further information on the settings in the ARGUSpedia on the
instrument.
When you select the susceptibility "insecure (fast)", the red warning
"ATTENTION: susceptible" appears on the display.