Chapter 5 Parameter Description
- 93 -
The floor selector can display a maximum of two bits in a floor code. F2-01 to F2-56 are
used to set the medium and low bits of codes of floors 1 to 56. The thousands position
and hundreds position of a parameter value indicate the medium bits of the floor
display. The tens position and ones position indicate the low bits of the floor display.
The meaning of codes is as follows:
00–09: Display
"
0
"
to
"
9
"
10–35: Display
"
A
"
to
"
Z
"
36: Display
"
-
"
37–40: Reserved
Group FP: Protection Parameters
Parameter
No.
Parameter Name
Setting Range
Default
Unit
Property
FP-00
Protection password
0–65535
0
-
☆
If FP-00 is set to a non-zero value, you can enter the parameter interface to view or
modify parameters only after entering the correct password.
Parameter
No.
Parameter Name
Setting Range
Default
Unit
Property
FP-01
Parameter update
No: No function
Yes: Restore default
settings
0
-
☆
If it is set to 1, the default settings of parameters are restored.
Parameter
No.
Parameter Name
Setting Range
Default
Unit
Property
FP-02
Language selection
Chinese
English
0
-
☆
If it is set to 0, the display language is Chinese. If it is set to 1, the display language is
English.
Parameter
No.
Parameter Name
Setting Range
Default
Unit
Property
FP-03
Voice volume of the
touchscreen
0–10
A larger number
indicates a higher
volume.
8
-
☆
FP-04
Touchscreen
brightness
adjustment
0–10
A larger number
indicates a higher
brightness.
8
-
☆
FP-05
Energy-saving time of
the touchscreen
0–60
1
min
☆
If there is no operation after the time specified in FP-05 (Energy-saving time of the
touchscreen), the brightness of the touchscreen is reduced.