Chapter 5 Parameter Description
- 92 -
Parameter
No.
Parameter Name
Setting Range
Default
Unit
Property
F1-06
Special function key in
the lower right corner
0–29
0: No function
1–26: Letters from A
to Z
27: Display "-"
28: Reserved
29: Door switching
function
28
-
☆
These parameters are used for the function selection of special function keys in the
lower left and lower right corner. Their values are displayed when you press the keys.
0: No function
1–26: Letters from A to Z
27: Display
"
-
"
28:
Reserved
29: Door switching function
By default, the front door on the destination floor is selected during floor selection.
Before entering the destination floor number, you can press this key to switch from the
front door to the rear door.
Parameter
No.
Parameter Name
Setting Range
Default
Unit
Property
F1-07
Program function
selection
-
0
-
☆
Group F2: Floor Display Parameters
Parameter
No.
Parameter Name
Setting Range
Default
Unit
Property
F2-01
Code of floor 1
0000–4040
For floor code
setting, the medium
bits (two high bits)
and low bits (two
low bits) are set
separately. The
available codes
include:
00–09: Display
"
0
"
to
"
9
"
10–35: Display
"
A
"
to
"
Z
"
36: Display
"
-
"
37–40: Reserved
0001
-
☆
F2-02
Code of floor 2
0002
-
☆
F2-03
Code of floor 3
0003
-
☆
Display of floors 4 to 50
…
F2-51
Code of floor 51
0501
-
☆
F2-52
Code of floor 52
0502
-
☆
F2-53
Code of floor 53
0503
-
☆
F2-54
Code of floor 54
0504
-
☆
F2-55
Code of floor 55
0505
-
☆
F2-56
Code of floor 56
0506
-
☆