Chapter 5 Parameter Description
- 76 -
F4-11: Group control function selection 1
Bit
Function
Description
Default
Bit 5
Period setting
for the traffic
mode
It is used to set periods for the traffic mode.
1: User-defined traffic mode enabled. In this case,
the time parameters specified by the parameters in
group F3 are effective.
0: User-defined traffic mode disabled. In this case,
the time parameters specified by the parameters in
group F3 are ineffective.
0
Bit 6
to
Bit15
Reserved
Group FU: System Monitoring Parameters
Parameter
No.
Parameter
Name
Setting Range
Default
Unit
Property
FU-00
CAN
communication
quality 1 of
elevators under
group control
LED 1: Communication
quality of elevator 1
LED 2: Communication
quality of elevator 2
LED 3: Communication
quality of elevator 3
LED 4: Communication
quality of elevator 4
LED 5: Communication
quality of elevator 5
0
-
●
FU-01
CAN
communication
quality 2 of
elevators under
group control
LED 1: Communication
quality of elevator 6
LED 2: Communication
quality of elevator 7
LED 3: Communication
quality of elevator 8
LED 4: Reserved
LED 5: Reserved
0
-
●
FU-00 displays the communication quality of the GCB and elevators 1 to 5.
As shown in the following figure, five LEDs from right to left are numbered 1, 2, 3, 4, and
5.
5
4
3
2
1
Figure 5-1
Example of communication quality of an elevator