Chapter 5 Parameter Description
- 68 -
0: Unused, indicating that the output terminal has no function
1 to 16: Reserved.
Group F2: Zoning Parameters
Parameter
No.
Parameter Name
Setting Range
Default
Unit
Property
F2-00
Zoning function
enabling in different
traffic modes
0–65535
Bit0: Energy-saving
mode
Bit1: Normal traffic
mode
Bit2: Up peak mode
Bit3: Down peak mode
Bit4: Sudden peak hour
mode
Bit5 to Bit15: Reserved
0
-
☆
The zoning function can be used in various traffic modes. In each mode, one binary bit
is used to specify whether the zoning function is enabled. The value 1 indicates that the
zoning function is enabled, and 0 indicates that the zoning function is disabled.
Bit
Function
Description
Bit0
Energy-saving mode
0
Zoing function is disabled.
1
Zoing function is enabled.
Bit1
Normal traffic mode
0
Zoing function is disabled.
1
Zoing function is enabled.
Bit2
Up peak traffic
0
Zoing function is disabled.
1
Zoing function is enabled.
Bit3
Down peak traffic
0
Zoing function is disabled.
1
Zoing function is enabled.
Bit4
Sudden peak hour
0
Zoing function is disabled.
1
Zoing function is enabled.
Bit5 to Bit15
Reserved
Parameter
No.
Name
Setting Range
Default
Property
Unit
F2-01
Zoning function setting
0: User-defined zoning
1: Intelligent zoning
0
-
☆
It is used to set the zoning function.
0: User-defined zoning
It works together with parameters F2-03 to F2-10 to define zones. The system uses the
zones specified by parameters F2-03 to F2-10.
1: Intelligent zoning
The system calculates and defines zones automatically based on the data collected by
SD card.