- 59 -
Parameter Table
Parameter
Parameter Name
Setting Range
Unit Default Commission
F4-38
DI active mode selection
(Normal: low level
active)
DI5 active mode:
0: Normal
1: Opposite
DI4 active mode:
0: Normal
1: Opposite
DI3 active mode:
0: Normal
1: Opposite
DI2 active mode:
0: Normal
1: Opposite
DI1 active mode:
0: Normal
1: Opposite
7-segment
00000 to 11111 (binary)
N.A
00000
-
F4-39
DI active mode selection
2
DI8 active mode:
0: Normal
1: Opposite
DI7 active mode:
0: Normal
1: Opposite
DI6 active mode:
0: Normal
1: Opposite
7-segment
00000 to 11111 (binary)
N.A
00000
-
Group F5: output terminals
Parameter
Parameter Name
Setting Range
Unit Default Commission
F5-00
FM terminal output
mode
0: High-speed pulse output (FMP)
1: ON/OFF output (FMR)
N.A
1
-
F5-01
FMR function
(open-collector
output terminal)
Attention!
Set F5-00 = 1 when FM
is used as MC or Brake
output.
0: No output
1: AC drive running
2: Fault output (stop)
3: Frequency-level detection
FDT1 output
4: Frequency reached
5: Zero-speed running (no output
at stop)
6: Motor overload pre-warning
7: AC drive overload pre-warning
8: Set count value reached
N.A
2
-