- 53 -
Parameter Table
7
Parameter Table
Group F0: fundamental
Parameter
Parameter Name
Setting Range
Unit
Default
Commission
F0-01
Motor 1 control mode
0: Sensor-less flux vector control
(SFVC)
2: V/F control
N.A
2
-
F0-02
Command source
selection
0: Operating panel control (LED
off)
1: Terminal control (LED on)
2: Communication control (LED
flashing)
N.A
1
-
F0-03
Main frequency source
X selection
2: AI-1
3: AI-2
4: AI-3
6: Multi-reference
N.A
6
-
F0-07
Frequency source
selection
0: Main frequency source X
N.A
0
-
F0-09
Rotation direction
0: Same direction
1: Reverse direction
N.A
0
-
F0-10
Maximum frequency
50.00 to 100.00
Hz
50.00
-
F0-15
Carrier frequency
0.5 to 11.0
(SVC mode: 0.5 to 9)
(V/F mode: 0.5 to 11)
kHz
Model
dependant
-
F0-17
Acceleration time 1
0.00 to 650.00 (F0-19 = 2)
0.0 to 6500.0 (F0-19 = 1)
0 to 65000 (F0-19 = 0)
s
3.0
-
F0-18
Deceleration time 1
0.00 to 650.00 (F0-19 = 2)
0.0 to 6500.0 (F0-19 = 1)
0 to 65000 (F0-19 = 0)
s
2.0
-
F0-19
Acceleration/
Deceleration time unit
0: 1
1: 0.1
2: 0.01
s
1
1