9.0 OPERATING INSTRUCTIONS
TS1A–13A
http://air.irco.com
39
User Setpoint Menu
#
NAME
DESCRIPTION
VALUES
1
Drain Valve Control
Drain Valve Control Technique
1 = Manual
2 = Automatic
2
Drain Valve Open Time
Manual Drain Valve Open Time
1 to 10 seconds
3
Drain Valve Closed Time
Manual Drain Valve Closed Time
1 to 45 minutes
4
MODBUS Control
MODBUS Control State
1 = Enabled
2 = Disabled
5
MODBUS Address
MODBUS Local Address
1 to 247
6
PORO Control
PORO Control State
1 = Enabled
2 = Disabled
The values displayed on the bar graphs are interpreted as follows:
Each light on the bar graph represents a number.
Add together the numbers represented by the illuminated lights to
get the displayed value.
Display Value = 8 + 2 + 1 = 11
The displayed value in the example above is 11.
In the display shown above, the left side shows the setpoint function (in
this case a display value of 3 would indicate the Drain Valve Closed
Time). The right side shows the setpoint value (in this case a display
value of 22 would indicate 22 minutes). In summary, the Drain Valve
Closed Time is set to 22 minutes.
Содержание TS10A
Страница 2: ......
Страница 10: ...5 0 SAFETY TS1A 13A http air irco com 8 5 3 TEXT DECALS NORTH AMERICA ...
Страница 50: ......
Страница 52: ......
Страница 60: ...5 0 SECURITE TS1A 13A http air irco com 8 5 3 DÉCALCOMANIES DES TEXTES AMÉRIQUE DU NORD ...
Страница 101: ......
Страница 102: ......
Страница 104: ......
Страница 112: ...5 0 SEGURANÇA TS1A 13A http air irco com 8 5 3 AUTOCOLANTES DE TEXTO AMÉRICA DO NORTE ...
Страница 152: ......
Страница 161: ...5 0 SEGURIDAD TS1A 13A http air irco com 8 5 3 CALCOMANÍAS DE TEXTO AMÉRICA DEL NORTE ...
Страница 203: ......
Страница 204: ......