25
( )
Book 54757919 (5/02)
WARNING
Do not connect the air discharge on this unit
onto a common header with any other unit of any
description, or any other source of compressed
air, without first making sure a check--valve is
used between the header and the unit. If this unit
is connected in parallel with another unit of
higher discharge pressure and capacity, a safety
hazard could occur in a back--flow condition.
WARNING
Unrestricted air flow from a hose will result in a
whipping motion of the hose which can cause
serious injury or death. A safety device must be
attached to the hose at the source of supply to
reduce pressure in case of hose failure or other
sudden pressure release. Reference: OSHA
regulation 29 CFR Section 1926.302 (b).
Air hose restraining cable installation:
Secure hose restraining cable at each end to prevent
accidental hose whipping. At the machine--side of the
air hose, install and secure one end of the hose
restraining cable on the 3” nipple on the inlet side of the
3” service valve. Install the other end of the hose
restraining cable over the main hose connector.
Install suitable 3” air hose between service valve on
unit and point of air use. The air hose must be rated for
outdoor use and for pressurized air service. Minimum
rating is 250
_
F (121
_
C) and 200 psig (HP) or 425 psig
(XHP).
BEFORE STARTING
Open service valves.
Inspect the complete installation including remote fuel
lines (if any) and air hose routing and connections.
Check battery for proper connections and condition.
WARNING
Combustible gas can cause severe burns,
blindness or death. Keep sparks and open flame
away from battery.
•
Check the compressor lubricating oil level. The
proper oil level is labeled on the compressor sump
sight glass.
•
Check engine oil level. The proper level is
labeled on the engine dipstick. Add oil when
required. Do not overfill.
•
To
jump--start,
connect
the
positive
booster/charger cable to the 24VDC positive (+)
terminal of the battery. Then connect the negative
booster/charger cable to the engine block...Not to
the negative (--) terminal of the weak battery. After
starting, disconnect the negative (--) cable from
engine block; then from the booster battery/charger.
Disconnect positive (+) cable from both batteries.
WARNING
Do not remove the cap from a HOT engine
radiator. The sudden release of pressure from a
heated cooling system can result in a loss of
coolant and possible severe personal injury.
WARNING
Hot pressurized fluid can cause serious burns.
Do not open radiator while hot.
Check coolant to assure coolant level is at minimum
level when the unit is cold.
Check engine coolant level by removing the radiator
top cap and looking for coolant in the filler neck of
the radiator. Add coolant as required. Insure that
radiator cap is installed properly and tightened.
Note: This machine will not allow engine starting if
engine coolant is low.
Содержание HP1300WCU
Страница 57: ...57 Book 54757919 5 02 Replace this sheet with 11 x 17 System Schematic Sheet 1 of 5...
Страница 58: ...58 Book 54757919 5 02 Replace this sheet with 11 x 17 System Schematic Sheet 2 of 5...
Страница 59: ...59 Book 54757919 5 02 Replace this sheet with 11 x 17 System Schematic Sheet 3 of 5...
Страница 60: ...60 Book 54757919 5 02 Replace this sheet with 11 x 17 System Schematic Sheet 4 of 5...
Страница 61: ...61 Book 54757919 5 02 Replace this sheet with 11 x 17 System Schematic Sheet 5 of 5...
Страница 75: ...75 Book 54757919 5 02 54699657 Deutsch Terminal Removal Tool 54749643 Packard Metri Pack Removal Tool...