36
( )
Book 54757919 (5/02)
This bypass does not provide any filtration but does
allow a maximum flow of compressor lubricating oil
to preclude any possible damage from loss of oil.
Also the design of the filter prevents any washing--off
of any dirt during oil bypassing.
NOTICE
The oil filter must be replaced every 1000 hours
of operation.
To service the oil filters it will first be necessary to
shut the unit down. Wipe off any external dirt and oil
from the exterior of the filter to minimize any
contamination from entering the lubrication system.
Proceed as follows:
WARNING
High pressure air can cause severe injury or
death from hot oil and flying parts. Always
relieve pressure before removing caps, plugs,
covers or other parts from pressurized air
system.
1. Open the service air valve(s) to ensure that
system is relieved of all pressure. Close the valve(s).
2. Turn
the
spin--on
filter
element
counterclockwise to remove it from the filter housing.
Inspect the filter element and then discard.
Note:
If there is any indication of formation of
varnishes, shellacs or lacquers on the oil filter
element, it is a warning the compressor lubricating
oil has improper characteristics and should be
immediately changed.
3. Inspect the oil filter head to be sure the gasket
was removed with the oil filter element. Clean the
gasket seal area on the oil filter head.
Installing a new oil filter element when the old gasket
remains on the oil filter head will cause an oil leak
and can cause property damage.
4. Lubricate the new filter gasket with the same oil
being used in the machine.
5. Install new filter by turning element clockwise
until gasket makes initial contact. Tighten an
additional 1/2 to 3/4 turn.
6. Start unit and allow to build up to rated pressure.
Check for leaks before placing unit back into service.
FASTENERS
Visually check entire unit in regard to bolts, nuts and
screws being properly secured. Spot check several
capscrews and nuts for proper torque. If any are
found loose, a more thorough inspection must be
made. Take corrective action.
COMPRESSOR OIL
The lubricating and cooling oil must be replaced
every 1000 hours of operation or six (6) months,
whichever comes first.
ENGINE COOLING FAN DRIVE
The heat exchanger or cooling fan is driven by a
single belt arrangement from the engine. Inspect the
cooling fan belt weekly. These belts should be
maintained at the proper tension by the auto tension
system on the engine.
EXTERIOR FINISH CARE
This unit was painted and heat cured at the factory
with a high quality, thermoset polyester powder
coating. The following care will ensure the longest
possible life from this finish.
1.
If necessary to remove dust, pollen, etc.
from housing, wash with water and soap
or dish washing liquid detergent. Do not
scrub with a rough cloth, pad, etc.
2.
If grease removal is needed, a fast
evaporating alcohol or chlorinated
solvent can be used. Note: This may
cause some dulling of the paint finish.
Содержание HP1300WCU
Страница 57: ...57 Book 54757919 5 02 Replace this sheet with 11 x 17 System Schematic Sheet 1 of 5...
Страница 58: ...58 Book 54757919 5 02 Replace this sheet with 11 x 17 System Schematic Sheet 2 of 5...
Страница 59: ...59 Book 54757919 5 02 Replace this sheet with 11 x 17 System Schematic Sheet 3 of 5...
Страница 60: ...60 Book 54757919 5 02 Replace this sheet with 11 x 17 System Schematic Sheet 4 of 5...
Страница 61: ...61 Book 54757919 5 02 Replace this sheet with 11 x 17 System Schematic Sheet 5 of 5...
Страница 75: ...75 Book 54757919 5 02 54699657 Deutsch Terminal Removal Tool 54749643 Packard Metri Pack Removal Tool...