TITAN GO Product Manual |
Wiring and Connections
INGENIA | 2022-07-14 08:35:14
80
Specification
Analog input 1
Type of inputs
Isolated. Differential. ESD protected
ESD capability
± 8 kV (contact)
Analog input resolution
12 bits
Maximum operating voltage
±10 V
Maximum common mode voltage (Analog input 2)
±10 V
Maximum voltage on any pin (referred to GND)
10 V
1st order filter cutting frequency (-3dB)
116 kHz
Sampling rate (max)
10 ksps
Next figure shows how to interface differential and single ended voltage sources to the differential analog input 1.
The differential analog input is typically used as a command source or feedback signal.