![INGENIA Titan GO Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/ingenia/titan-go/titan-go_product-manual_2058554096.webp)
TITAN GO Product Manual |
Wiring and Connections
INGENIA | 2022-07-14 08:35:14
96
•
•
•
•
•
•
•
•
•
•
Manufact
urer
Part Number
Image
Description
IXXAT
USB-to-CAN V2
Professional
USB to CAN dual channel interface.
High-speed CAN channels in two separate RJ-45
connectors.
Cable adapter to 9-pin D-SUB CAN.
Vector
Informatik
VN1630
USB to CAN or CAN FD four channel (two
connectors) interface .
High-speed CAN channels in two separate 9-pin D-
SUB CAN connectors.
Highly robust plastic housing.
7.8.3.2 CAN wiring recommendations
Build CAN network using cables with
2-pairs of twisted wires
(2 wires/pair) as follows: one pair for CAN_H
with CAN_L and the other pair for CAN_V+ with CAN_GND.
Cable impedance must be of 105 to 135
Ω
(120
Ω
typical) and a capacitance below 30 pF/meter.
Whenever possible, use bus links between the CAN nodes.
Avoid using stubs
(a "T" connection, where a
derivation is taken from the main bus). If stubs cannot be avoided keep them as short as possible. For
maximum speed (1 Mbps), use a stub length lower than 0.3 meters.
For a total CAN bus length
over 40 meters
, it is mandatory to
use shielded twisted cables
. Connect the
cable shield to protective earth at both ends. Ensure that the cable shield is connected to the connector
shield, as connection to host protective earth is usually soldered inside the connector.
Содержание Titan GO
Страница 19: ...TITAN GO Product Manual Product Description INGENIA 2022 07 14 08 35 14 19 ...
Страница 56: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 56 ...
Страница 89: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 89 ...
Страница 101: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 101 ...