An example of CAN wiring is shown in the next figure.
When installing CANopen communication, ensure that each servo drive is allocated a unique ID.
Otherwise, CANopen network may hang.
Termination resistor
The use of bus termination resistors (120
Ω
between CAN_L and CAN_H), one at each end of the bus, is
essential for correct operation of the CAN bus. Even with only one Titan Go connected, mount the
termination resistor to ensure CAN bus operation.
Do not use wirewound resistors
, which are inductive.