TITAN GO Product Manual |
Wiring and Connections
INGENIA | 2022-07-14 08:35:14
63
This interface accepts 0-5 V level input signals. Inputs are pulled up to 5 V, so industry standard open collector and
logic output hall effect sensors can be connected. Next table summarizes digital halls inputs main features:
Specification
Value
Type of inputs
Isolated
Single ended with pull-up and low pass filter
ESD protected
Number of inputs
3
ESD capability
IEC 61000-4-2 (ESD) ± 15 kV (air), ± 8 kV (contact)
Voltage range
0 ~ 5 V
Maximum voltage range
-0.5 ~ 5.5 V
Maximum recommended working frequency
1 kHz
1st order filter cutting frequency (-3dB)
16 kHz
Sampling frequency
10 ksps
Type of sensors
Open collector
Logic output
Push-pull output
Pull-up resistor value
1 k
Ω
Next figure shows the circuit model of the digital Halls inputs.
Содержание Titan GO
Страница 19: ...TITAN GO Product Manual Product Description INGENIA 2022 07 14 08 35 14 19 ...
Страница 56: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 56 ...
Страница 89: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 89 ...
Страница 101: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 101 ...