307
SIN+
Sine wave with 2.5 V offset and 0.5 Vpp
Sin-cos signal description
SIN-
Same as SIN+, but with 180º phase shift
COS+
Cosine with 2.5 V offset and 0.5 Vpp
COS-
Same as COS+, but with 180º phase shift
REF+
One sine half wave per revolution as index pulse
REF-
Same as REF+, but with 180º phase shift
We are aware that the signals are not always perfect sine and cosines. This is why Jupiter includes sin-cos calibration and adjustment parameters. See the
EMCL parameters
Analog encoder (Sin-Cos encoder)
An automatic calibration based on Lissajous curves is included in
, this allows adjusting the feedback easily.
Next table summarizes analog encoder inputs main features.
Specification