Maximum voltage
130 V
Maximum current
1A (
Typical electrical Turn-On/Turn-Off time
80 µs / 500 µs Max. (resistive load)
5 ms / 10 ms (inductive load)
Protection
Overload and short circuit (maximum 10 s)
Overvoltage
Overtemperature
Turn-on and turn-off times are specified for loads at 24 VDC and 700 mA. Turn-on and turn-off times are defined as the time to reach 95% of nominal
current. The real time required for mechanical braking will strongly depend on the brake model and its dynamic behavior.
External temperature sensor wiring
An external temperature sensor (PTC thermistor) can be connected to the Jupiter to measure the motor temperature. The following picture shows the recommended
connection.