Installation Guide
INGENIA MOTION CONTROL
Confidential and proprietary information.
Unauthorized Copies Prohibited.
Page
of
201
307
Type of input (input 2)
Differential
ESD protected
Type of input (input 1)
Single ended
ESD protected
ESD capability (input 2)
IEC 61000-4-2 (ESD) ± 15 kV (air), ± 8 kV (contact)
ESD capability (input 1)
IEC 61000-4-2 (ESD) ± 15 kV (air), ± 8 kV (contact)
Analog input resolution
12 bits
Maximum operating differential voltage
(input 2)
±10 V
Maximum operating voltage (input 1)
0 ~ 5 V
Maximum voltage on any input pin for input 2 (referred to GND)
24 V
Maximum voltage on any input pin for input 1 (referred to GND)
24 V
Maximum working frequency
10 kHz for input 1
50 kHz for input 2
Input impedance
>10 kΩ
Next table shows the Jupiter Servo Drive analog inputs voltage range.
Input
Max. differential voltage (Analog In+) – (Analog In-)
Analog input 1
0 V to + 5 V
Analog input 2
-10 V to + 10 V