Single input mode
In this mode, only one input signal is used. PWM command is a PWM signal whose duty cycle sets the target position, velocity or torque.
For velocity mode, a duty cycle of 50% corresponds with 0 rpm. A 0% duty cycle corresponds with the maximum velocity in one direction, and a 100% duty
corresponds to the maximum velocity in the opposite direction. Position and torque modes work in a similar way.
This mode uses High speed digital input 2.
for information about connector´s position and pinout, and see
Connectors position and pinout
High-speed (HS) digital inputs interface
about digital inputs. Next figure shows how to connect this input: