Step and direction.
PWM command (single and dual input mode).
Encoder following / electronic gearing.
For command sources 3, 4, 5 and 6 general purpose inputs are used. Next Table illustrates command source options and which parameters can be controlled.
page for further details on configuration parameters.
Command source
Controlled parameter
Network interface
Position, velocity, torque
Standalone
Position, velocity, torque
Step and direction
Position
Encoder following / electronic gearing
Position
Analog input (+/- 10 V o 0 – 5 V)
Position, velocity, torque
PWM command
Position, velocity, torque