Brake connection using an external power supply
The external supply connection must be used when the brake nominal voltage is higher than the power supply voltage.
An internal freewheling diode in anti-parallel with the brake is provided on board. This will prevent inductive kicking (voltage rise when current through the
inductor falls to zero).
The Jupiter brake output can also be used as a general purpose high current digital output (GPO5). This can be easily configured using